Specifications

αCM-015 Dimensions

( mm )

Rail width W ( mm )
A
B
C
75
25
167.7
203.5
100
50
180.2
216
125
75
192.7
228.5
Note1 : The A, B, C dimensions change according to the width of the applicable rail.

αCM-015 Specifications

Type
Single-speed type
Model ( For 200V - 440V )
αCM-015
Capacity ( ton )
150
Headroom ( mm ) *
425
Standard lift ( m )
3
Motor output ( kW )
0.55
Lifting speed ( m / min )
50 Hz
9
60 Hz
11
Traverse motor output ( kW )
0.3
Traversing speed ( m / min )
High-speed type ( standard )
( 50Hz / 60Hz )
20 / 24
Low-speed type
( 50Hz / 60Hz )
10 / 12
Traverse rail width ( mm )
75 ・ 100 ・ 125
Minimum traverse turning radius ( mm )
900
Minimum height of traverse rail ( mm )
100
Net weight ( kg )
36
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) Use three-phase power source.
4 ) The power cord of 0.5m extending from the trolley ( 4-core: 1 pc for earth ) is supplied.
5 ) Put the low-speed type "S" between the model symbol when specifying low traversing speed ( example : αCMS-015 ); when there is no specification, the speed will be nomal ( standard ).
6 ) The three-phase traverse motor has E-class insulation, and the short time rating is 30 min.
Specifications and dimensions are subject to change without notice.

αCM-025 Dimensions

( mm )

Rail width W ( mm )
A
B
C
75
25
167.7
203.5
100
50
180.2
216
125
75
192.7
228.5
Note1 : The A, B, C dimensions change according to the width of the applicable rail.

αCM-025 Specifications

Type
Single-speed type
Model ( For 200V - 440V )
αCM-025
Capacity ( ton )
250
Headroom ( mm ) *
425
Standard lift ( m )
3
Motor output ( kW )
0.55
Lifting speed ( m / min )
50 Hz
9
60 Hz
11
Traverse motor output ( kW )
0.3
Traversing speed ( m / min )
High-speed type ( standard )
( 50Hz / 60Hz )
20 / 24
Low-speed type
( 50Hz / 60Hz )
10 / 12
Traverse rail width ( mm )
75 ・ 100 ・ 125
Minimum traverse turning radius ( mm )
900
Minimum height of traverse rail ( mm )
100
Net weight ( kg )
36
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) Use three-phase power source.
4 ) The power cord of 0.5m extending from the trolley ( 4-core: 1 pc for earth ) is supplied.
5 ) Put the low-speed type "S" between the model symbol when specifying low traversing speed ( example : αCMS-015 ); when there is no specification, the speed will be nomal ( standard ).
6 ) The three-phase traverse motor has E-class insulation, and the short time rating is 30 min.
Specifications and dimensions are subject to change without notice.

αCM-050 Dimensions

( mm )

Rail width W ( mm )
A
B
C
75
25
167.7
203.5
100
50
180.2
216
125
75
192.7
228.5
Note1 : The A, B, C dimensions change according to the width of the applicable rail.

αCM-050 Specifications

Type
Single-speed type
Model ( For 200V - 440V )
αCM-050
Capacity ( ton )
500
Headroom ( mm ) *
505
Standard lift ( m )
3
Motor output ( kW )
0.55
Lifting speed ( m / min )
50 Hz
4.5
60 Hz
5.5
Traverse motor output ( kW )
0.3
Traversing speed ( m / min )
High-speed type ( standard )
( 50Hz / 60Hz )
20 / 24
Low-speed type
( 50Hz / 60Hz )
10 / 12
Traverse rail width ( mm )
75 ・ 100 ・ 125
Minimum traverse turning radius ( mm )
900
Minimum height of traverse rail ( mm )
100
Net weight ( kg )
38.5
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) Use three-phase power source.
4 ) The power cord of 0.5m extending from the trolley ( 4-core: 1 pc for earth ) is supplied.
5 ) Put the low-speed type "S" between the model symbol when specifying low traversing speed ( example : αCMS-015 ); when there is no specification, the speed will be nomal ( standard ).
6 ) The three-phase traverse motor has E-class insulation, and the short time rating is 30 min.
Specifications and dimensions are subject to change without notice.
TOPへ戻る